Skip to content

Engine Fire Panel


Back to Overhead


Engine Fire Panel

API Documentation: FIRE Panel API

Description

The Engine Fire Panel is used to control the engine fire detection and extinguishing systems.

Usage

ENG 1(2)(3)(4) FIRE pb

  • IN, dark and closed:
    • Normal position.
    • No fire is detected.
  • IN, illuminated and closed:
    • Fire is detected. The FIRE light of the ENG MASTER panel comes on, and also indicates the affected engine.
    • Associated with the following ECAM warning: ENG 1(2)(3)(4) FIRE
    • The light remains on, until the fire is extinguished, regardless of the position of the ENG FIRE pb.
    • The flight crew is pressing the ENG FIRE Panel Test pb (Refer to Test pb).
  • OUT, illuminated and open (pressed):
    • All associated systems are isolated from the engine.
    • The aural fire warning stops.
    • The fire extinguishing system is armed, the bottles are ready to discharge.

AGENT 1(2) pb

  • AUTO:
    • Normal position.
  • SQUIB:
    • The squibs of the fire extinguisher bottles are armed.
    • The fire extinguisher bottles are ready to discharge extinguisher agent.
    • When pressed, the extinguisher bottles discharge and the SQUIB light goes off.
  • DISCH:
    • The fire extinguisher bottle discharges or is empty.
  • SQUIB & DISCH:
    • The flight crew is pressing the ENG FIRE panel TEST pb (Refer to TEST pb).

TEST pb

  • Tests the engines, the APU and the main landing gear bay fire warnings.
  • When pressed for at least three seconds, and until released, tests the operation of the engine fire detection and extinguishing system:
    • The continuous repetitive chime sounds.
    • The MASTER WARN lights flash.
    • The ECAM displays ENG FIRE, APU FIRE and MLG FIRE warnings titles.
    • All ENG FIRE pb come on red.
    • The APU FIRE pb comes on red.
    • All SQUIB lights of the AGENT pb come on.
    • All DISCH lights of the AGENT pb come on.
    • All FIRE lights on the ENG MASTER panel come on.

Back to Overhead